Product information "ZPS Pro Ideal circulation system"
The ZPS PRO IDEAL circulation pump is delivered fully assembled and ready for connection, mounted on a stainless steel base plate.
Equipped with a 3 kW heating element, it features a green indicator light, a thermostat, and a safety temperature limiter. The control box of the circulation pump for barns has a summer and winter operating mode. In summer, the ZPS PRO IDEAL circulation pump saves considerable energy costs because it only switches on every half hour instead of running continuously. This also prevents the pump rotor from seizing. Naturally, the heating element is switched off in summer. In winter, the circulation pump operates with thermostatically controlled heating. This ensures frost-free drinking troughs even in the depths of winter. The pipe length is approximately 250 meters with a 1-inch diameter, and the connection cable is 1.50 meters long (excluding the power plug). The Lister ZPS PRO IDEAL circulation pump comes with a check valve, a vent valve, a pressure relief valve, and a T-fitting.
Using the ZPS PRO IDEAL Circulation Pump
Have the ZPS PRO IDEAL circulation pump installed by an authorized professional in accordance with all applicable regulations. The circulation pump is designed to circulate the water supply for drinking troughs. The integrated heating element prevents the water from cooling down too much and freezing, thus ensuring frost-free drinking troughs. The ZPS PRO IDEAL is specifically designed for the demands of stables. It ensures efficient water circulation, which is essential for maintaining water quality in drinking troughs. Its use ensures that the water remains fresh, clean, and free of contaminants, which is of utmost importance for the health of the horses. Stagnant water quickly becomes contaminated with germs, but the water movement keeps it fresh and prevents germs from taking hold. Do you let your animals graze in the pasture during the winter? Then we have the perfect frost-free watering system for you: the DRINKING POST 2100 for horses – a frost-proof waterer that doesn't require electricity, the DRINKING POST 1800 for cattle – a frost-proof pasture waterer that doesn't require electricity, or the DRINKING POST 1200 for sheep!
Information about the ZPS PRO IDEAL circulation pump
Thanks to its constant water circulation, the ZPS PRO IDEAL circulation pump also ensures that even individual, rarely used drinking troughs don't become contaminated. Bacteria multiply rapidly in stagnant water. Furthermore, animals generally prefer to drink water that is at a comfortable temperature rather than water that is too cold. This way, your animals are optimally supplied with fresh drinking water via the frost-proof waterers, even in winter. This keeps them healthy and happy. However, switch the circulation pump to winter mode well before the onset of frost, when temperatures drop below 5 degrees Celsius. This way, the screw-in heating element will automatically start heating when the preset temperature is reached. This prevents unnecessary energy waste on frost-proof drinking troughs. After winter, switch the ZPS PRO IDEAL back to summer mode, and the heating element will cease operation. You can find practical drinking troughs in the Lister247 shop, such as the plastic horse trough with a pressure tongue or the plastic cattle trough with a pressure tongue.
The advantages of the ZPS PRO IDEAL circulation pump at a glance:
The ready-to-connect circulation pump is delivered fully assembled on a stainless steel base plate.
The pump: High-efficiency pump (max. 45 watts), with lower power consumption for the same pumping performance.
The heating element: 3 kW (with green indicator light, thermostat, and safety temperature limiter).
The control box has a switch for summer and winter operation.
In summer mode, the circulation pump switches on automatically every half hour, thus saving considerable energy costs compared to conventional circulation systems (which run continuously) and preventing the pump rotor from seizing. Naturally, the thermostat-controlled heating unit does not operate in summer.
In winter mode, the pump runs continuously with the thermostatically controlled heating.
Connection cable: 1.50 m (without plug)
Pipe length: approx. 250 meters with a 1" pipe diameter
Accessories for the circulation system: check valve, air vent, pressure relief valve, and T-fitting
Technical data:
Voltage: 230 volts
Pump: max. 45 watt high-efficiency pump
Heating element: 3 kW complete
Pipe length: approx. 250 Meters with 1" pipe diameter
Connection cable: 1.50 m (without mains plug)
Control box: with switch for summer and winter operation
Summer operation: daily automatic switch-on (½ hour) of the circulation pump
Winter operation: continuous pump operation and thermostatically controlled heating operation (thermostat-controlled heating unit is not in operation during summer operation)
Accessories: check valve, air vent, pressure relief valve and T-piece